COGGING OR MAGNETIC LOCKING:Sometimes,even when
full voltage is applied to the stator winding,the rotor of a 3-phase cage
induction motor fails to start.This happens when the number of stator and rotor
slots are either equal or have an integral ratio.With the number of stator and
rotor slots are either equal or have an integral ratio.
The number of the stator slots equal to or an
integral multiple of the rotor slots,storng alignment forces is produced
between the stator and rotor.as a result of these forces an alignment torque
greater than the accelerating torque with consequent failure of the motor to
start.thus a locking is created betweenthe stator and rotor teeth.this
condition is known as cogging or magnetic locking.